Follow us:
Log in | Register | Go to french website FR website


X




Forgot your password?

Tropical Dental Journal - 1st Pan African international dental journal


Tropical Dental Journal



encart_diam_crosspharm

Consultez les mentions légales (RCP) des médicaments disponibles dans votre pays


Medical library

Browse all APIDPM's publications and enjoy the subscription offers in APIDPM Online store

Do you want to subscribe to Tropical Dental Journal ? CConsult articles? Visit APIDPM Online store - Read more


SPONSORING
APIDPM supports African medical congresses

You organize a medical congress in Africa?
APIDPM stands by your side to promote it. As of now, ask for your « Partnership » file.

Read more


TEAM OF READERS
Expertise to share?

Do you have expertise in a specific field and would like to contribute your experience and help our authors publish better articles?

Contact Nathalie!


Archives / Articles consultation


Published in French in Tropical Dental Journal Volume 40 - September 2017 pages 9-19

Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknessesFracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses est évalué 4.42857142857143 étoiles par les abonnés Tropical Dental Journal Online

Article Open access

Authors : C. Rouhana, E. Nasr, Hardan, E. Zebouni - Lebanon


Résumé

Introduction : L’objectif de cette étude est d’évaluer la résistance à la fracture des couronnes monolithiques postérieures faites en vitrocéramique renforcée par le silicate de lithium enrichi au dioxyde de zirconium (SLZ), et de déterminer l’épaisseur occlusale minimale requise pour ce type de couronnes.
Matériels et méthodes : L’empreinte numérique d’une taille de molaire inférieure d’un dentoforme (Frasaco, USA) a été prise afin de réaliser 40 couronnes monolithiques divisées en 4 groupes (n = 10) : les couronnes au dislicate de lithium (DL) (IPS e.max CAD ; Ivoclar Vivadent, Schaan, Liechtenstein) ont été faites avec une épaisseur occlusale de 1.5 mm et les couronnes au SLZ (Vita Suprinity, Vita Zahnfabrik, Bad Säckingen, Germany) ont été faites avec des épaisseurs occlusales de 1.5 mm, 1 mm et 0,7 mm. Toutes les couronnes ont été collées sur des moignons en polyméthacrylate de méthyle (PMMA) à l’aide d’un ciment résine autoadhésif (Permacem 2.0, DMG, Germany). Les échantillons ont subi des cycles thermiques (5°C-55°C, 2000 cycles), puis ont été testés par une charge axiale jusqu’à fracture à l’aide d’une machine d’essais universelle (YL-01, Germany) à une vitesse de 1 mm/min. L’analyse statistique des données a été réalisée à l’aide du logiciel statistique Statistical Package Software For Social Science (SPSS for Windows, version 18.0, Chicago, IL, USA).
Résultats : La différence entre le SLZ et DL, testés à la même épaisseur, n’a pas été significative (p-value = 0.838). La résistance moyenne à la fracture variait significativement selon les différentes épaisseurs occlusales des couronnes faites au SLZ (-p-value < 0.001). Les moyennes des charges de fracture trouvées sont de 965 ± 76.28 N pour le SLZ (0.7 mm), 1422.6 ± 86.744 N pour le SLZ (1 mm), 1866.1 ± 92.231 N pour le SLZ (1.5 mm) et 1908.9 ± 240.538 N pour le DL (1.5 mm).
Conclusion : La résistance à la fracture des couronnes au SLZ est comparable à celle des couronnes monolithiques au DL et une épaisseur occlusale minimale de 1 mm est nécessaire pour supporter les charges masticatoires.

Abstract
Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses

Introduction: The aim of this study was to evaluate the fracture resistance of posterior monolithic crowns made by zirconia reinforced lithium silicate (ZLS) glass ceramic and to establish the minimal required occlusal thickness for this type of crowns.
Materials and methods: A digital scan of a prepared lower molar of a dentoform (Frasaco, USA) was taken in order to make 40 monolithic crowns divided in 4 groups (n = 10): Lithium disilicate (IPS e.maxCAD ; Ivoclar Vivadent, Schaan, Liechtenstein) crowns were fabricated with an occlusal thickness of 1.5 mm and ZLS (Vita Suprinity, Vita Zahnfabrik, Bad Säckingen, Germany) crowns were fabricated with 3 different occlusal thicknesses: 1.5 mm, 1 mm and 0.7 mm. All crowns were cemented on polymethyl methacrylate (PMMA) dies using a self-adhesive luting material (Permacem 2.0, DMG, Germany). Samples underwent thermocycling (5°C-55°C, 2000 cycles) and then were loaded axially to fracture using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using the program Statistical Package Software For Social Science (SPSS for Windows, version 18.0, Chicago, IL, USA).
Results: No statistically significant (p = 0.838) difference in the fracture resistance was found between the ZLS and the LD tested at the same occlusal thickness. The fracture resistance varied significantly depending on the different occlusal thicknesses of the ZLS crowns (-p-value < 0.001). The mean fracture loads were 965 ± 76.28 N for ZLS (0.7 mm), 1422.6 ± 86.744 N for ZLS (1 mm), 1866.1 ± 92.231 N for ZLS (1.5 mm) and 1908.9 ± 240.538 N for LD (1.5 mm).
Conclusion: ZLS and LD crowns have comparable fracture strength and a minimal occlusal thickness of 1 mm for the ZLS crowns is needed to withstand masticatory loads.

icone adobe Read ( PDF )

This article is currently rated Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses is rated 4.42857142857143 stars (4.4 stars) by the subscribers of Tropical Dental Journal Online.
It has been viewed 8825 times, downloaded 13 times and rated 7 times.  No comment has yet been added about this article

Back

N.B.: to add a comment, type your text in the form available under the full article.

X


Already registered?


Not yet registered?


Fast buy?





Tropical Dental Journal


CONTACT US

Address

  • Espace Santé 3
    521, avenue de Rome
    83500 La Seyne sur mer - France

Phone

  • +33 4 94 63 24 99

Contact us


APIDPM

Who are we?

Use rights


Publisher:

Valid XHTML 1.0 Strict CSS Valide !