Follow us:
Log in | Register | Go to french website FR website


X




Forgot your password?

Tropical Dental Journal - 1st Pan African international dental journal


Tropical Dental Journal


encart_diam_ferrer

Consultez les mentions légales (RCP) des médicaments disponibles dans votre pays


Medical library

Browse all APIDPM's publications and enjoy the subscription offers in APIDPM Online store

Do you want to subscribe to Tropical Dental Journal ? CConsult articles? Visit APIDPM Online store - Read more


SPONSORING
APIDPM supports African medical congresses

You organize a medical congress in Africa?
APIDPM stands by your side to promote it. As of now, ask for your « Partnership » file.

Read more


TEAM OF READERS
Expertise to share?

Do you have expertise in a specific field and would like to contribute your experience and help our authors publish better articles?

Contact Nathalie!


Most read - Most commented

TOP 10 ARTICLES / Best rated


Ranked N° 1 on 651 articles

Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: A new concept in composite layering - Part I

J. Manauta, A. Salat, A. Putignano, W. Devoto, G. Paolone, L.S. Hardan - Italie
Published in English in Tropical Dental Journal - N° 146 - June 2014 - 5-16   Article Open access  

See/hide abstract

Résumé

Restoring an anterior tooth has always been a challenge, regarding the shade matching, the choice of colors, opacities, translucencies of our composites and the final anatomical outcome.
This article proposes a new method for color matching and a clinical stratification using a simple and reproducible procedure for anterior restorations.
The physical and optical characteristics of enamel and dentine will be studied and applied to our dental materials that we are using to restore anterior teeth.

Summary
Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: A new concept in composite layering - Part I

La restauration d'une dent antérieure a toujours été un défi, en ce qui concerne la prise de la teinte, le choix des couleurs, les différentes opacités et translucidités des composites et le résultat anatomique final.
Cet article propose une nouvelle méthode de choix de couleur et de la stratification clinique utilisant des procédures simples et reproductibles pour les restaurations antérieures.
Les caractéristiques physiques et optiques de l'émail et de la dentine seront étudiées et appliquées à nos produits dentaires que nous utilisons pour restaurer les dents antérieures.

Keywords: Stratification, teinte, dentine, émail

Read the article

This article is currently rated Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: 
A new concept in composite layering - Part I is rated 4.82608695652174 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 4367 times, downloaded 31 times et rated 23 times.  No comment has yet been added about this article


Ranked N° 2 on 651 articles

Proposing a novel protocol for halitosis assessment

S.O. Nwhator, I. Uhunmwangho - Nigéria
Published in English in Tropical Dental Journal - N° 144 - December 2013 - 15-24   Article Open access  

See/hide abstract

Résumé

Objectif : Il s'agit d'un document de synthèse destiné à élaborer un protocole simple pour l'évaluation complète et rapide de l'halitose.
Matériels et méthodes : Un vaste protocole a été développé par une revue de la littérature afin d'identifier tous les facteurs étiologiques possibles identifiés des études précédentes. Le protocole qui en résulte a été présenté comme un formulaire comprenant les antécédents médicaux et dentaires ainsi qu'un examen oral et parodontal. Les aspects médicaux pertinents, une rubrique de consultation ORL ainsi que gastro-intestinale ont également été incluses. Chaque type de données recueillies à partir de la littérature a été inclus afin de dresser une liste incluant tous les facteurs possibles. Les facteurs découverts à partir de l'expérience des auteurs ont, également, été inclus dans le protocole.
Résultats : Une longue liste de facteurs a été identifiée dans la littérature qui comprend des facteurs médicaux, dentaires, parodontaux, alimentaires et autres. Tout ceci a été inclus dans le formulaire qui en résulte. Une liste de pré-évaluation a également été incluse.
Conclusion : L'halitose a une étiologie multiforme. Un protocole facile à utiliser permet à une évaluation complète mais rapide de l'halitose.

Summary
Proposing a novel protocol for halitosis assessment

Aim: This is a review paper intended to develop a simple protocol for the comprehensive yet rapid assessment of halitosis.
Materials and methods: An extensive protocol was developed through a review of literature to identify all possible etiological factors as have been identified by previous workers. The resulting protocol was presented as a form including extensive medical and dental history as well as oral and periodontal examination. Relevant medical aspects, an otolaryngology (ENT) consultation section as well as a gastrointestinal consultation were also included. Every bit of evidence gathered from literature was included in order to develop a list that's as inclusive of all possible contributing factors as possible. Factors discovered from the experience of the authors were also included in the protocol.
Results: A long list of factors was identified in literature including medical, dental, periodontal, diet and others. All these were included in the resulting form and a pre-evaluation checklist was also included.
Conclusion: Halitosis is multifaceted in etiology. A simple easy-to-use protocol helps in an extensive yet rapid evaluation of halitosis.

Keywords: halitose, diagnostic, protocole,

Read the article

This article is currently rated Proposing a novel protocol for halitosis assessment is rated 4.66666666666667 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 5651 times, downloaded 74 times et rated 30 times.  1 comment has yet been added about this article


Ranked N° 3 on 651 articles

Three-dimensional facial architecture in normodivergent class I Caucasian subjects

J.V. Ghoubril, F.M. Abou Obeid - Liban
Published in English in Tropical Dental Journal - N° 142 - June 2013 - 5-14   Article Open access  

See/hide abstract

Résumé

Introduction : L'objectif de cette étude est de (1) définir l'architecture faciale chez les patients Caucasiens normo-divergents en classe I squelettique et dentaire à partir d'une acquisition tomodensitométrique tridimensionnelle en utilisant l'analyse de Treil, et (2) trouver un concept d'équilibre ou de normalité individuelle concernant les paramètres linéaires, angulaires et volumiques.
Matériels et méthodes : L'échantillon comporte 60 sujets également répartis entre les deux sexes. A partir de repères anatomiques situés sur les axes trigéminaux de la croissance neuro-matricielle de la face, un modèle tridimensionnel de l'architecture maxillo-faciale a été construit.
Résultats : Les paramètres linéaires et volumiques sont plus grands chez les hommes (0,000 < p < 0,044) à l'exception des largeurs mandibulaires antérieure et postérieure. Le dimorphisme sexuel n'a pas été observé au niveau des paramètres angulaires. Les tests de corrélation ont montré que le volume total de la charpente augmente avec les profondeurs sous et sus-orbitaires, la largeur mandibulaire postérieure et la hauteur faciale (0,526 < r < 0,777), alors qu'il n'était pas associé à la largeur maxillo-orbitaire (0,252 < r < 0,389). Les volumes orbitaire et total sont plus corrélés avec la largeur mandibulaire postérieure qu'ave cl'antérieure. Le volume maxillo-mandibulaire est corrélé avec la profondeur orbitaire (0,591<r<0,742) plus que le volume orbitaire (0,482 < r < 0,589).
Conclusion : Les résultats nous ont permis d'établir des normes céphalométriques tridimensionnelles, et de remplacer le principe de normalité, qui est une valeur moyenne des paramètres calculés, par la notion d'équilibre individuel entre entités volumétriques. Tandis que les dimensions sagittale et verticale affectent les changements volumétriques de la charpente, la dimension transversale n'a aucune influence.

Summary
Three-dimensional facial architecture in normodivergent class I Caucasian subjects

Introduction: The aims of this study were to (1) define facial architecture in Caucasian patients with normodivergent, skeletal and dental class I using Treil's cephalometric analysis, which is based on computed tomography (CT), and (2) develop a scheme to determine individual balance or normality in relation to linear, angular and volumetric parameters.
Material and methods: The CT data of 60 adult subjects were equally divided between both genders. Based on anatomical points located along the trigeminal neuro-matricial facial growth axes, a three dimensional maxillo-facial architecture was constructed.
Results: Volumetric and linear parameters were greater in males (0.000 < p< 0.044) except for the anterior and posterior mandibular width. Sexual dimorphism was not observed with angular parameters. There was no correlation between volumetric and angular parameters. The correlation tests showed that the total volume of the frame increases with infraorbital depth, supraorbital depth, posterior mandibular width and facial height (0.526 < r < 0.777), while it was not associated with the maxillo-orbital width (0.252 < r < 0.389). Total and orbital volumes were more correlated with posterior than with anterior mandibular width. Maxillo-mandibular volume of the frame was more cor-related with orbital depth (0.591 < r < 0.742) than the orbital volume (0.482 <r < 0.589).
Conclusions: The results allowed us to establish three-dimensional cephalometric standards, and to replace the tenet of normality, which is a mean value of calculated parameters, by the concept of individual balance among volumetric entities. While sagittal and vertical dimensions affect volumetric changes of the frame, the transverse dimension does not.

Keywords: équilibre individuel, scanner, normalité, normes,

Read the article

This article is currently rated Three-dimensional facial architecture in normodivergent class I Caucasian subjects is rated 4.66666666666667 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 3493 times, downloaded 20 times et rated 12 times.  No comment has yet been added about this article


Ranked N° 4 on 651 articles

Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: A new concept in composite layering - Part II

J. Manauta, A. Salat, A. Putignano, W. Devoto, G. Paolone, L.S. Hardan - Italie
Published in English in Tropical Dental Journal - N° 147 - September 2014 - 5-13   Article Open access  

See/hide abstract

Résumé

Lors de la restauration d'une dent antérieure, la prise de la teinte est l'un des points cruciaux auxquels nous sommes confrontés dans le but d'avoir un résultat esthétique final.
Après avoir étudié les caractéristiques physiques et optiques de l'émail et de la dentine dans la première partie de cet article, cette deuxième partie va proposer une nouvelle méthode de choix de couleur et une stratification clinique en utilisant une procédure simple et reproductible pour les restaurations antérieures avec une seule teinte dentine et une teinte émail.

Summary
Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: A new concept in composite layering - Part II

While restoring an anterior tooth, shade matching is one of the crucial points that we can face to have an esthetic final outcome.
After studying the physical and optical characteristics of enamel and dentine in the first part of this article, the second part will propose a new method for color matching and a clinical stratification using a simple and reproducible procedure for anterior restorations with only one dentine and one enamel shade.

Keywords: Esthétique dentaire, émail dentaire, dentine, résine composite

Read the article

This article is currently rated Stratification in anterior teeth using one dentine shade and a predefined thickness of enamel: A new concept in composite layering - Part II is rated 4.6 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 3685 times, downloaded 38 times et rated 30 times.  No comment has yet been added about this article


Ranked N° 5 on 651 articles

Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part I

J. Manauta, A. Salat, A. Putignano, W. Devoto, C.F. Villares, L.S. Hardan - Espagne
Published in English in Tropical Dental Journal - N° 155 - September 2016 - 11-19   Article Open access  

See/hide abstract

Résumé

Le plus grand défi lors de la restauration des dents antérieures est la reproduction fidèle de la couleur. La teinte, la saturation, la luminosité, l’opacité, la translucidité, l'intensité et l'anatomie doivent être soulevées pour être reproduites. La lumière est nécessaire pour distinguer les détails de la dent, sachant qu’il y a une forte relation entre la nature de la lumière et les composants d'une dent naturelle. Cet article explique comment choisir la teinte et la technique de stratification pour restaurer les dents antérieures en choisissant les matériaux adéquats pour imiter la nature. Les propriétés physiques de la lumière naturelle et polarisée seront également étudiées pour comprendre leur association avec les matériaux dentaires et les dents naturelles afin de les utiliser suivant la meilleure recette.

Summary
Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part I

The biggest challenge while restoring anterior teeth is shade matching. Hue, chroma, value, opacity, translucency, intensity and anatomy must be seen to be reproduced. To see we need light, knowing that there is a strong relation between the nature of light and the components of natural teeth.
This article enlightens the way to do the shade matching and the stratification of anterior teeth by choosing the relevant materials to mimic the nature.
The physical properties of natural and polarized light will be studied to understand their correlation with dental materials and natural teeth to use them in the best combination.

Keywords:

Couleur, teinte, résines composite, émail, dentine

Read the article

This article is currently rated Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part I is rated 4.55555555555556 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 4472 times, downloaded 25 times et rated 9 times.  No comment has yet been added about this article


Ranked N° 6 on 651 articles

Implications of choice of products and impression technique on the thickness of the dento-prosthetic interface of the CAD-CAM crowns

E. Nasr, N. Kamel, E. H. Moussa, L. Hardan, E. Zebouni - Liban
Published in French in Tropical Dental Journal - N° 154 - March 2016 - 25-37   Article Open access  

See/hide abstract

Résumé

Le but de cette étude est de trouver quel type de produit à empreinte est capable d’aboutir à une couronne Procera présentant le minimum d’épaisseur au niveau du joint dento-prothétique et de l’interface, compte tenu de l’effet de la surdimension des répliques et des variations dimensionnelles des produits à empreinte dans le temps. La précision de l’adaptation marginale va donc dépendre de la surdimension de la réplique de la préparation clinique après lecture (scanning). Trois différents types de produits à empreinte : polyéthers de viscosité moyenne (Impregum - 3M-ESPE, Allemagne), silicones polyvinyl siloxanes type A (Putty + Very Light) et (Heavy + Light) (Express - 3M-ESPE, Allemagne), ont été utilisés pour la prise de quinze empreintes d’un modèle prototype initial d’une arcade dentée supérieure, comportant deux carottes en nickel-chrome. Les coulées des empreintes ont été effectuées avec le plâtre type IV (Zhermack, Italie), sur lesquels trente couronnes CAD-CAM (Procera) ont été élaborées suivant une valeur de surdimension rendue constante (K). Cette surdimension n’intéresse que les parois axio-occlusales sans toutefois toucher à la valeur tridimensionnelle de limites cervicales jusqu’à leur intersection avec les parois axiales. L’épaisseur de l’interface dento-prothétique a été ensuite étudiée à trois niveaux : à 0, à 1 et à 2 mm. Le facteur produit d’empreinte a une influence statistiquement significative sur les épaisseurs de l’interface dento-prothétique et ceci aux trois niveaux de mesure. La technique d’empreinte la plus compressive Putty + Very Light a donné le meilleur résultat aux trois niveaux précités. Les résultats obtenus après analyse des échantillons sous microscope optique ont montré une différence significative entre les trois produits (p-value < 0.05). La calibration de cette surdimension K, intéressant uniquement les parois axio-occlusales, devrait donc être fonction des propriétés physico-chimiques du produit d’empreinte utilisé ainsi que de la technique dans le but d’aboutir à un joint dento-prothétique optimal.

Summary
Implications of choice of products and impression technique on the thickness of the dento-prosthetic interface of the CAD-CAM crowns

The purpose of this study is to find out what type of impression material is able to achieve a CAD-CAM (Procera) crown with minimal thickness at the dental-prosthetic interface, taking into account the effect of the oversize replica and dimensional variations of the impression materials over time. The accuracy of the marginal adaptation will therefore depend on the oversize replica of clinical preparation controlled by the constant K. Three different types of impression materials: medium viscosity polyether (Impregum 3M-ESPE, Germany), silicones polyvinyl siloxane A (Putty + Very Light) and (Heavy + Light) (Express 3M-ESPE, Germany), were used for making impressions of fifteen initial prototype maxillary teeth made of nickel chrome. The cast of the impressions were poured with plaster type IV (Zhermack, Italy), on which thirty Procera crowns were fabricated. The thickness of the dental-prosthetic interface was then studied at three levels: 0, 1 and 2 mm. The results show that the impression material has a statistically significant impact on the thickness of the dental-prosthetic interface at all three levels. The most compressive impression technique, Putty + Very Light gave the best results at the three levels pre-cited. The results analyzed under optical microscopy show a statistically significant difference between the three impression material products (p-value < 0.05). The calibration constant K, according to each clinical situation, can therefore lead to optimal dental-prosthetic inter-face.

Keywords:

Technique d’empreinte dentaire, produits d’empreinte dentaire, CAD-CAM, Procera, Procera allceram, impregum, polyvinyl siloxane, interface dento-prothétique

Read the article

This article is currently rated Implications of choice of products and impression technique on the thickness of the dento-prosthetic interface of the CAD-CAM crowns is rated 4.5 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 4629 times, downloaded 14 times et rated 8 times.  No comment has yet been added about this article


Ranked N° 7 on 651 articles

Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses

C. Rouhana, E. Nasr, Hardan, E. Zebouni - Liban
Published in French in Tropical Dental Journal - N° 159 - September 2017 - 9-19   Article Open access  

See/hide abstract

Résumé

Introduction : L’objectif de cette étude est d’évaluer la résistance à la fracture des couronnes monolithiques postérieures faites en vitrocéramique renforcée par le silicate de lithium enrichi au dioxyde de zirconium (SLZ), et de déterminer l’épaisseur occlusale minimale requise pour ce type de couronnes.
Matériels et méthodes : L’empreinte numérique d’une taille de molaire inférieure d’un dentoforme (Frasaco, USA) a été prise afin de réaliser 40 couronnes monolithiques divisées en 4 groupes (n = 10) : les couronnes au dislicate de lithium (DL) (IPS e.max CAD ; Ivoclar Vivadent, Schaan, Liechtenstein) ont été faites avec une épaisseur occlusale de 1.5 mm et les couronnes au SLZ (Vita Suprinity, Vita Zahnfabrik, Bad Säckingen, Germany) ont été faites avec des épaisseurs occlusales de 1.5 mm, 1 mm et 0,7 mm. Toutes les couronnes ont été collées sur des moignons en polyméthacrylate de méthyle (PMMA) à l’aide d’un ciment résine autoadhésif (Permacem 2.0, DMG, Germany). Les échantillons ont subi des cycles thermiques (5°C-55°C, 2000 cycles), puis ont été testés par une charge axiale jusqu’à fracture à l’aide d’une machine d’essais universelle (YL-01, Germany) à une vitesse de 1 mm/min. L’analyse statistique des données a été réalisée à l’aide du logiciel statistique Statistical Package Software For Social Science (SPSS for Windows, version 18.0, Chicago, IL, USA).
Résultats : La différence entre le SLZ et DL, testés à la même épaisseur, n’a pas été significative (p-value = 0.838). La résistance moyenne à la fracture variait significativement selon les différentes épaisseurs occlusales des couronnes faites au SLZ (-p-value < 0.001). Les moyennes des charges de fracture trouvées sont de 965 ± 76.28 N pour le SLZ (0.7 mm), 1422.6 ± 86.744 N pour le SLZ (1 mm), 1866.1 ± 92.231 N pour le SLZ (1.5 mm) et 1908.9 ± 240.538 N pour le DL (1.5 mm).
Conclusion : La résistance à la fracture des couronnes au SLZ est comparable à celle des couronnes monolithiques au DL et une épaisseur occlusale minimale de 1 mm est nécessaire pour supporter les charges masticatoires.

Summary
Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses

Introduction: The aim of this study was to evaluate the fracture resistance of posterior monolithic crowns made by zirconia reinforced lithium silicate (ZLS) glass ceramic and to establish the minimal required occlusal thickness for this type of crowns.
Materials and methods: A digital scan of a prepared lower molar of a dentoform (Frasaco, USA) was taken in order to make 40 monolithic crowns divided in 4 groups (n = 10): Lithium disilicate (IPS e.maxCAD ; Ivoclar Vivadent, Schaan, Liechtenstein) crowns were fabricated with an occlusal thickness of 1.5 mm and ZLS (Vita Suprinity, Vita Zahnfabrik, Bad Säckingen, Germany) crowns were fabricated with 3 different occlusal thicknesses: 1.5 mm, 1 mm and 0.7 mm. All crowns were cemented on polymethyl methacrylate (PMMA) dies using a self-adhesive luting material (Permacem 2.0, DMG, Germany). Samples underwent thermocycling (5°C-55°C, 2000 cycles) and then were loaded axially to fracture using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using the program Statistical Package Software For Social Science (SPSS for Windows, version 18.0, Chicago, IL, USA).
Results: No statistically significant (p = 0.838) difference in the fracture resistance was found between the ZLS and the LD tested at the same occlusal thickness. The fracture resistance varied significantly depending on the different occlusal thicknesses of the ZLS crowns (-p-value < 0.001). The mean fracture loads were 965 ± 76.28 N for ZLS (0.7 mm), 1422.6 ± 86.744 N for ZLS (1 mm), 1866.1 ± 92.231 N for ZLS (1.5 mm) and 1908.9 ± 240.538 N for LD (1.5 mm).
Conclusion: ZLS and LD crowns have comparable fracture strength and a minimal occlusal thickness of 1 mm for the ZLS crowns is needed to withstand masticatory loads.

Keywords:

Résistance à la fracture, épaisseur occlusale, conception et fabrication assistées par ordinateur, silicate de lithium renforcé en dioxyde de Zirconium

Read the article

This article is currently rated Fracture strength of zirconia reinforced lithium silicate at different occlusal thicknesses is rated 4.42857142857143 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 8826 times, downloaded 13 times et rated 7 times.  No comment has yet been added about this article


Ranked N° 8 on 651 articles

Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II

L.S. Hardan, E.W. Amm, A. Ghayad, C. Ghosn, A. Khraisat - Liban
Published in English in Tropical Dental Journal - N° 126 - June 2009 - 29-37   Article Open access  

See/hide abstract

Résumé

Introduction : Pour réduire la rétraction de polymérisation des résines composites et après l’introduction de la « polymérisation lente et progressive » par GORACCI et al. en 1992, plusieurs appareils à photopolymériser ont présenté la polymérisation «soft-start», en plus du mode de polymérisation classique à intensité lumineuse maximale. Cette étude a testé si cette polymérisation lente et progressive pourra réduire le décollage marginal en diminuant le stress interne des composites, sachant que les études qui ont comparé ce mode de polymérisation sont rares.
Matériel et Méthodes : Cent vingt cavités classe II ont été préparées au niveau des faces mésiales et distales de prémolaires humaines extraites. Ces dents ont été réparties aléatoirement en 4 groupes (n = 15). Au niveau de chaque dent, les cavités mésiales ont été restaurées avec le composite micro-hybride Filtek Z250 (3M ESPE) et les cavités distales ont été restaurées avec le composite nano-chargé Filtek Suprême (3M ESPE). Dans cette étude, l’appareil à photopolymériser utilisé était un appareil halogène conventionnel, le QHL 75 (Dentsply), modifié en ajoutant un dispositif de réglage électronique, contrôlé par un logiciel spécial qui nous permet d’avoir 4 modes de polymérisation différents comme suit :

  • Groupe A : Polymérisation standard : Exposition de 20 secondes à 700 mW/cm².
  • Groupe B : Polymérisation intermittente modifiée : Exposition de 2 secondes à 700 mW/cm², suivie par 5 secondes à 0 mW/cm² puis 20 secondes à 700 mW/cm².
  • Groupe C : Polymérisation progressive modifiée : Exposition de 20 secondes avec une augmentation progressive de l’intensité pour atteindre 700 mW/cm² puis de 20 secondes à 700 mW/cm².
  • Groupe D : Polymérisation lente et progressive : Exposition de 4 minutes avec une augmentation progressive de l’intensité pour atteindre 700 mW/cm².

Les dents ont été stockées dans de l’eau à 37°C pendant 48 heures, polies, puis soumises à un thermocyclage (3000 cycles entre 5°C et 55°C). Toutes les dents ont été immergées dans une solution de bleu de méthylène à 2% pour une durée de 12 heures à 37°C, sectionnées et évaluées au niveau de l’interface marginale. Les données ont été analysées statistiquement par le test de l’analyse de variance à deux facteurs suivie par des comparaisons multiples de Tukey HSD.
Résultats : La différence statistique entre les deux types de composites n’a pas été significative (p = 0,682), de même que pour l’effet de l’interaction (p = 0,678). Concernant les techniques de photopolymérisation testées, la différence était significative (p = 0,014). Le test de Tukey HSD a indiqué que la moyenne des scores du groupe A (M = 2.40, SD=1.102) était significativement différente de celle du groupe D (M=1.30, SD=1.393, p=0.010). Pas de différence significative entre le groupe D et le groupe B (M=1.63, SD=1.351, p=0.767), ainsi que le groupe C (M=1.60, SD=1.404, p=0.819). Il y avait une différence entre le groupe A (M=2.40, SD=1.102) et le groupe B (M=1.63, SD=1.351) ainsi que le groupe C (M=1.60, SD=1.404). Cependant, lorsque le test de Tukey HSD a été utilisé cette différence n’était plus statistiquement significative entre le groupe A et les groupes B et C (p=0,122 et p=0.098).
Conclusions : Il y avait une différence statistiquement significative, dans la formation de microhiatus, entre la « polymérisation lente et progressive » et la polymérisation standard, cependant il n’y avait pas de différence statistiquement significative entre les composites nano-chargés et micro-hybrides polymérisés avec les différents modes de polymérisation.

Summary
Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II

Introduction: To reduce the polymerization shrinkage of the composite resins and after the introduction of the "slow and gradual polymerization" by GORACCI et al. in 1992, many light curing units (LCU) presented the “soft-start polymerization” in addition to the classical high light intensity mode. This study investigated whether this slow and gradual polymerization has the ability of reducing the marginal debonding, by minimizing the internal stress of the composite, knowing that rare are the studies which compared this mode of polymerization.
Material and methods: One hundred twenty Class II cavities were prepared at the mesial and the distal side of human extracted premolars. The teeth were randomly divided into four groups (n=15). In each tooth the mesial Class II cavities were restored with the micro-hybrid resin composite Filtek Z250 (3M ESPE) and the distal Class II cavities were restored with the nano-filled resin composite Filtek Supreme (3M ESPE) The light curing unit used in this study was a conventional quartz tungsten halogen (QTH) curing light, the QHL 75 (Dentsply) modified by adding a regulating electronic device, controlled by a special software that gives 4 different modes of polymerization as follows:

  • Group A: Standard polymerization: Exposure for 20 seconds at 700 mW/cm², this group was used as control.
  • Group B: Modified pulse-delay polymerization: Exposure for 2 seconds at 700 mW/cm², 5 seconds at 0 mW/cm², then 20 seconds at 700mW/cm².
  • Group C: Modified ramp polymerization: Exposure for 20 seconds with a slow rise of the intensity to reach the 700 mW/cm² then 20 seconds at 700 mW/cm2.
  • Group D: Slow and Gradual polymerization: Exposure for 4 minutes with a slow rise of the intensity to reach 700 mW/cm².

The teeth were stored in water at 37°C for 48 hours, then finished and subjected to thermocycling (3000 cycles between 5°C and 55°C). All the teeth were immersed in 2% methylene blue solution for 12 hours at 37°C, sectioned, and evaluated at the gingival margins. Data were statistically analyzed by two-way analysis of variance followed by Tukey HSD multiple comparisons.
Results: The main effect for the type of composites (p= 0.682), and the interaction effect (p=0.678) did not reach statistical significance. There was a statistically significant main effect for the type of polymerization used (p=0.014). Post-hoc comparisons using the Tukey HSD test indicated that the mean score for the Group A (M=2.40, SD= 1.102) was significantly different from the group D (M= 1.30, SD= 1.393, p= 0.010). The group D did not differ significantly from group B (M= 1.63, SD= 1.351, p=0.767), and group C (M= 1.60, SD= 1.404, p=0.819). There was a difference between the group A (M=2.40, SD= 1.102), group B (M= 1.63, SD= 1.351) and group C (M= 1.60, SD= 1.404). However, when the Tukey HSD was used, no statistically significant differences between Group A, B and C were found (p=0.122 and p =0.098).
Conclusions: There was a statistically significant difference in micro leakage between the “slow and gradual polymerization” and the standard polymerization, however no significant differences were found when using the nano-filled or the micro-hybrid composite materials cured with different polymerization regimens.

Keywords: polymérisation, intensité lumineuse, composites,

Read the article

This article is currently rated Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II is rated 4.33333333333333 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 3822 times, downloaded 10 times et rated 6 times.  No comment has yet been added about this article


Ranked N° 9 on 651 articles

Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part II

J. Manauta, A. Salat, A. Putignano, W. Devoto, C.F. Villares, L.S. Hardan - Espagne
Published in English in Tropical Dental Journal - N° 156 - December 2016 - 5-15   Article Open access  

See/hide abstract

Résumé

Avec le temps, la lumière naturelle et polarisée ont prouvé leur importance et leurs utilités dans la photographie dentaire.
Après l'étude des propriétés physiques de la lumière naturelle et polarisée, dans la première partie de cet article, pour comprendre leur corrélation avec les matériaux dentaires et les dents naturelles, afin de les utiliser dans la meilleure combinaison, cette deuxième partie illustre l'importance de l'image polarisée dans le choix des couleurs, comment la manipuler et la manière de son application dans les cas cliniques.

Summary
Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part II

With time, natural and polarized light proved their importance and utility in dental photography.
After studying the physical properties of natural and polarized light, in the first part of this article, to understand their correlation with dental materials and natural teeth and how to use them in the best combination, this second part will illustrate the importance of a polarized image in color matching, how to manipulate it and how to apply it in clinical cases.

Keywords:

Couleur, teinte, lumière polarisée,résines composites, émail, dentine

Read the article

This article is currently rated Natural, polarized light and the choice of composite: a key to success in shade matching of direct anterior restorations- Part II is rated 4.33333333333333 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 4539 times, downloaded 9 times et rated 6 times.  No comment has yet been added about this article


Ranked N° 10 on 651 articles

An 18 month evaluation of MM-MTA pulpotomy on primary decayed molars

J.C. Abou Chédid, N. Mchayleh, I. Khalil, B. Melki, L.S. Hardan - Liban
Published in French in Tropical Dental Journal - N° 152 - December 2015 - 17-24   Article Open access  

See/hide abstract

Résumé

La pulpotomie est la thérapeutique pulpaire la plus fréquemment réalisée en dentisterie pédiatrique. C'est celle qui présente le plus de controverse. La technique utilisant le formocrésol est la plus répandue. Mais, les craintes concernant la diffusion systémique et la potentielle toxicité, allergénicité, carcinogénicité, et mutagénicité du formaldéhyde ont conduit à rechercher des alternatives à ce produit.
Afin d’évaluer, selon des critères cliniques et radiologiques, l’action du Micro Mega Mineral Trioxide Aggregate (MM-MTA), qui permet de se passer du formocrésol, 40 molaires temporaires cariées ont subi une pulpotomie à l’aide de ce matériau. Les contrôles post-opératoires ont été réalisés à 1, 6, 12 et 18 mois, à la recherche de douleur spontanée ou provoquée, de mobilité dentaire pathologique, d’abcès ou de fistule, de résorption radiculaire interne ou externe pathologique, de destruction osseuse inter et/ou péri-apicale ou d’oblitération canalaire. La douleur était inexistante à 18 mois. Trente-six molaires traitées au MM-MTA ne présentaient pas de mobilité ou de douleur alors que les résorptions internes et externes n'ont été rencontrées qu'au niveau d'une molaire. Par ailleurs, une molaire présentait un abcès sans fistule au bout de 12 mois. Ces observations ont été comparées à celles relatives à la pulpotomie au formocrésol, au sulfate ferrique, au MTA et au laser, en utilisant le test de Chi-deux, test χ². L’abondance de résultats positifs démontre fortement que la pulpotomie au MM-MTA sur des molaires temporaires cariées est une technique prometteuse.

Summary
An 18 month evaluation of MM-MTA pulpotomy on primary decayed molars

Pulpotomy is the most performed and controversial therapeutic in pediatric dentistry. Formocresol is known to have a toxic effect on living tissues, a mutagenic and carcinogenic potential with a systemic uptake of formocresol via pulpotomized teeth, other alternative products have been investigated.
40 molars were pulpotomized using Micro Mega Mineral Trioxide Aggregate (MM-MTA), which eliminates the need for the use of formocresol. The effects of this material were evaluated both clinically and radiographically. Post-operative control examinations were performed at 1, 6, 12, and 18 months trying to detect spontaneous or stimulated pain, pathological tooth mobility, abscesses or fistulas, internal or external pathological tooth resorption, periapical bone destruction, or canal obliteration. Pain was absent at 18 months post operatively. Thirty six molar treated with the MM-MTA didn’t show any mobility or pain, one molar presented a pathological resorption and one molar presented an abscess without a fistula at 12 month. The observations were compared to others related to formocresol, ferric sulfate, MTA, and laser pulpotomies, using the Chi-square test x². The abundance of positive result strongly demonstrate that the MM-MTA pulpotomy on carious temporary molars is a promising technique.

Keywords: Pulpotomie, MM-MTA, dentisterie pédiatrique

Read the article

This article is currently rated An 18 month evaluation of MM-MTA pulpotomy on primary decayed molars   is rated 4.33333333333333 stars by the subscribers of Tropical Dental Journal Online.
It has been viewed 4641 times, downloaded 25 times et rated 6 times.  No comment has yet been added about this article




Tropical Dental Journal


CONTACT US

Address

  • Espace Santé 3
    521, avenue de Rome
    83500 La Seyne sur mer - France

Phone

  • +33 4 94 63 24 99

Contact us


APIDPM

Who are we?

Use rights


Publisher:

Valid XHTML 1.0 Strict CSS Valide !