Published in French in Tropical Dental Journal Volume 43 - December 2020 pages 5-17
Article Open access
Authors : C. Boueiz, P. Habre, E. Zebouni - Lebanon
Introduction : L'objectif de cette étude était d'évaluer la résistance à la rupture à l'interface suite à des contraintes de cisaillement de deux céramiques différentes sur une même base en Zircone, selon deux techniques différentes de montage de la céramique : CAD-On et stratification manuelle.
Matériels et méthodes : Vingt blocs en zircone IPS e.max® ZirCAD étaient préparés par la technique CAD-On. Vingt autres blocs en zircone IPS e.max® ZirCAD ont été frittés sur lesquels la céramique IPS e.max® Ceram a été monté au pinceau. Un groupe contrôle de 20 blocs a été préparé comportant une base en métal non-précieux Colado® CC sur lequel la céramique IPS InLine® a été montée par stratification. Tous les échantillons ont subi un thermocyclage. Le test de cisaillement a été réalisé à l'aide d'une machine de test universelle (YL 01-Germany).
Résultats : Cette étude a montré que la valeur du shear bond stress était significativement différente entre les groupes (p-value < 0,001). Elle était significativement plus élevée au niveau du groupe CAD-on (355,38 ± 82,51 MPa) et plus petite pour le groupe Céramique stratifiée /Cr-Co (145,82 ± 37,2 MPa) et le groupe Céramique stratifiée sur base en Zircone (160,08 ± 64,10 MPa). La différence entre Céramique stratifiée/Cr-Co et Céramique stratifiée sur base en Zircone n'a pas été significative (p-value = 0,762).
Conclusion : La force d'adhésion à l'interface joignant disilicate de lithium, vitrocéramique de fusion et zircone Y-TZP usinés suivant la technique CAD-On est la plus élevée. Ce qui semble améliorer la fiabilité clinique des restaurations fabriquées par CFAO.
Introduction: The objective of this study was to evaluate the fracture resistance at the interface following shear stresses of two different ceramics on the same Zirconia base, according to two different ceramic mounting techniques: CAD- On and manual stratification.
Materials and methods: Twenty IPS e.max®ZirCAD zirconia blocks were prepared using the CAD-On technique. A further 20 IPS e.max® ZirCAD zirconia blocks were sintered on which the IPS e.max® Ceram ceramic was layered. A 20-block control group was prepared with a Colado® CC non-precious metal base on which the IPS InLine® ceramic was laminated. All samples were thermocycled. The shear test was performed using a universal test machine (YL 01).
Results: This study showed that the value of shear bond stress was significantly different between groups (p-value < 0.001). It was significantly higher in the CAD-on group (355.38 ± 82.51 MPa) and smaller in the Laminated Ceramic/Cr-Co group (145.82 ± 37.42 MPa) and the Zirconia-based laminated ceramic group (160.08 ± 64.10 MPa). The difference between Laminated Ceramics/Cr-Co and Zirconia-based Ceramics was not significant (p-value = 0.762).
Conclusion: The adhesion strength at the interface joining lithium disilicate, fusion glass-ceramic and zirconia Y-TZP machined according to the CAD-On technique is the highest. This seems to improve the clinical reliability of restorations manufactured by CAD/CAM.
This article is currently rated (1.0 stars) by the subscribers of Tropical Dental Journal Online.
It has been viewed 5292 times, downloaded 4 times and rated 1 times.