Ce site utilise des cookies afin d'améliorer la navigation et mesurer la fréquentation. Pour en savoir plus, cliquez ici

bannière promotionnelle

Odonto-Stomatologie tropicale

Publié en Anglais dans Odonto-Stomatologie tropicale Volume 32 - Juin 2009 pages 29-37

Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II   Article Open access   Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II est évalué 4,33333333333333 étoiles par les abonnés APIDPM Santé tropicale

Auteurs : L.S. Hardan, E.W. Amm, A. Ghayad, C. Ghosn, A. Khraisat - Liban


Résumé

Introduction : Pour réduire la rétraction de polymérisation des résines composites et après l’introduction de la « polymérisation lente et progressive » par GORACCI et al. en 1992, plusieurs appareils à photopolymériser ont présenté la polymérisation «soft-start», en plus du mode de polymérisation classique à intensité lumineuse maximale. Cette étude a testé si cette polymérisation lente et progressive pourra réduire le décollage marginal en diminuant le stress interne des composites, sachant que les études qui ont comparé ce mode de polymérisation sont rares.
Matériel et Méthodes : Cent vingt cavités classe II ont été préparées au niveau des faces mésiales et distales de prémolaires humaines extraites. Ces dents ont été réparties aléatoirement en 4 groupes (n = 15). Au niveau de chaque dent, les cavités mésiales ont été restaurées avec le composite micro-hybride Filtek Z250 (3M ESPE) et les cavités distales ont été restaurées avec le composite nano-chargé Filtek Suprême (3M ESPE). Dans cette étude, l’appareil à photopolymériser utilisé était un appareil halogène conventionnel, le QHL 75 (Dentsply), modifié en ajoutant un dispositif de réglage électronique, contrôlé par un logiciel spécial qui nous permet d’avoir 4 modes de polymérisation différents comme suit :

  • Groupe A : Polymérisation standard : Exposition de 20 secondes à 700 mW/cm².
  • Groupe B : Polymérisation intermittente modifiée : Exposition de 2 secondes à 700 mW/cm², suivie par 5 secondes à 0 mW/cm² puis 20 secondes à 700 mW/cm².
  • Groupe C : Polymérisation progressive modifiée : Exposition de 20 secondes avec une augmentation progressive de l’intensité pour atteindre 700 mW/cm² puis de 20 secondes à 700 mW/cm².
  • Groupe D : Polymérisation lente et progressive : Exposition de 4 minutes avec une augmentation progressive de l’intensité pour atteindre 700 mW/cm².

Les dents ont été stockées dans de l’eau à 37°C pendant 48 heures, polies, puis soumises à un thermocyclage (3000 cycles entre 5°C et 55°C). Toutes les dents ont été immergées dans une solution de bleu de méthylène à 2% pour une durée de 12 heures à 37°C, sectionnées et évaluées au niveau de l’interface marginale. Les données ont été analysées statistiquement par le test de l’analyse de variance à deux facteurs suivie par des comparaisons multiples de Tukey HSD.
Résultats : La différence statistique entre les deux types de composites n’a pas été significative (p = 0,682), de même que pour l’effet de l’interaction (p = 0,678). Concernant les techniques de photopolymérisation testées, la différence était significative (p = 0,014). Le test de Tukey HSD a indiqué que la moyenne des scores du groupe A (M = 2.40, SD=1.102) était significativement différente de celle du groupe D (M=1.30, SD=1.393, p=0.010). Pas de différence significative entre le groupe D et le groupe B (M=1.63, SD=1.351, p=0.767), ainsi que le groupe C (M=1.60, SD=1.404, p=0.819). Il y avait une différence entre le groupe A (M=2.40, SD=1.102) et le groupe B (M=1.63, SD=1.351) ainsi que le groupe C (M=1.60, SD=1.404). Cependant, lorsque le test de Tukey HSD a été utilisé cette différence n’était plus statistiquement significative entre le groupe A et les groupes B et C (p=0,122 et p=0.098).
Conclusions : Il y avait une différence statistiquement significative, dans la formation de microhiatus, entre la « polymérisation lente et progressive » et la polymérisation standard, cependant il n’y avait pas de différence statistiquement significative entre les composites nano-chargés et micro-hybrides polymérisés avec les différents modes de polymérisation.

Abstract
Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II

Introduction: To reduce the polymerization shrinkage of the composite resins and after the introduction of the "slow and gradual polymerization" by GORACCI et al. in 1992, many light curing units (LCU) presented the “soft-start polymerization” in addition to the classical high light intensity mode. This study investigated whether this slow and gradual polymerization has the ability of reducing the marginal debonding, by minimizing the internal stress of the composite, knowing that rare are the studies which compared this mode of polymerization.
Material and methods: One hundred twenty Class II cavities were prepared at the mesial and the distal side of human extracted premolars. The teeth were randomly divided into four groups (n=15). In each tooth the mesial Class II cavities were restored with the micro-hybrid resin composite Filtek Z250 (3M ESPE) and the distal Class II cavities were restored with the nano-filled resin composite Filtek Supreme (3M ESPE) The light curing unit used in this study was a conventional quartz tungsten halogen (QTH) curing light, the QHL 75 (Dentsply) modified by adding a regulating electronic device, controlled by a special software that gives 4 different modes of polymerization as follows:

  • Group A: Standard polymerization: Exposure for 20 seconds at 700 mW/cm², this group was used as control.
  • Group B: Modified pulse-delay polymerization: Exposure for 2 seconds at 700 mW/cm², 5 seconds at 0 mW/cm², then 20 seconds at 700mW/cm².
  • Group C: Modified ramp polymerization: Exposure for 20 seconds with a slow rise of the intensity to reach the 700 mW/cm² then 20 seconds at 700 mW/cm2.
  • Group D: Slow and Gradual polymerization: Exposure for 4 minutes with a slow rise of the intensity to reach 700 mW/cm².

The teeth were stored in water at 37°C for 48 hours, then finished and subjected to thermocycling (3000 cycles between 5°C and 55°C). All the teeth were immersed in 2% methylene blue solution for 12 hours at 37°C, sectioned, and evaluated at the gingival margins. Data were statistically analyzed by two-way analysis of variance followed by Tukey HSD multiple comparisons.
Results: The main effect for the type of composites (p= 0.682), and the interaction effect (p=0.678) did not reach statistical significance. There was a statistically significant main effect for the type of polymerization used (p=0.014). Post-hoc comparisons using the Tukey HSD test indicated that the mean score for the Group A (M=2.40, SD= 1.102) was significantly different from the group D (M= 1.30, SD= 1.393, p= 0.010). The group D did not differ significantly from group B (M= 1.63, SD= 1.351, p=0.767), and group C (M= 1.60, SD= 1.404, p=0.819). There was a difference between the group A (M=2.40, SD= 1.102), group B (M= 1.63, SD= 1.351) and group C (M= 1.60, SD= 1.404). However, when the Tukey HSD was used, no statistically significant differences between Group A, B and C were found (p=0.122 and p =0.098).
Conclusions: There was a statistically significant difference in micro leakage between the “slow and gradual polymerization” and the standard polymerization, however no significant differences were found when using the nano-filled or the micro-hybrid composite materials cured with different polymerization regimens.

icone adobe Lire l'article (PDF)   Article Open access

Cet article est actuellement coté note (4,3 étoiles) par les abonnés de APIDPM Santé tropicale.
Il a été consulté 5118 fois, téléchargé 101 fois et évalué 6 fois.  Aucun commentaire n'a encore été ajouté à propos de cet article

Vous avez aimé cet article ? Partagez-le !

Retour - Sommaire de ce numéro

N. B. : pour ajouter un commentaire, tapez votre texte dans le formulaire mis à votre disposition sous l'article intégral.

X


Déjà inscrit ?


Pas inscrit ?


Visiteur occasionnel ?



annonce
L’Autorité Ivoirienne de Régulation Pharmaceutique rappelle que seul le pharmacien est habilité à délivrer des médicaments sûrs, conformes et adaptés à vos besoins.

FMC Diabète

encart
Médecins généralistes - Rejoignez l'École du Diabète de la FID en collaboration avec la Global Health Unit de Sanofi

encart
Éducateurs et éducatrices en diabétologie - Rejoignez l'École du Diabète de la FID en collaboration avec la Global Health Unit de Sanofi

Vous consacrez votre vie à prendre soin des autres.
Qui vous aide à vous épanouir ?

logo_sanofi

👉 La chaîne WhatsApp de Sanofi GHU


Des outils pour éduquer les patients

👉 FMC Paludisme - Strides


CONTACTEZ-NOUS

Adresse

Téléphone

CARTE DU SITE

Revue MAF

Revue OST

Actualités

Rubriques spécialités

Webinaires

Espaces labos

Valid XHTML 1.0 Strict CSS Valide !