Material and methods: One hundred twenty Class II cavities were prepared at the mesial and the distal side of human extracted premolars. The teeth were randomly divided into four groups (n=15). In each tooth the mesial Class II cavities were restored with the micro-hybrid resin composite Filtek Z250 (3M ESPE) and the distal Class II cavities were restored with the nano-filled resin composite Filtek Supreme (3M ESPE) The light curing unit used in this study was a conventional quartz tungsten halogen (QTH) curing light, the QHL 75 (Dentsply) modified by adding a regulating electronic device, controlled by a special software that gives 4 different modes of polymerization as follows:

The teeth were stored in water at 37°C for 48 hours, then finished and subjected to thermocycling (3000 cycles between 5°C and 55°C). All the teeth were immersed in 2% methylene blue solution for 12 hours at 37°C, sectioned, and evaluated at the gingival margins. Data were statistically analyzed by two-way analysis of variance followed by Tukey HSD multiple comparisons.
Results: The main effect for the type of composites (p= 0.682), and the interaction effect (p=0.678) did not reach statistical significance. There was a statistically significant main effect for the type of polymerization used (p=0.014). Post-hoc comparisons using the Tukey HSD test indicated that the mean score for the Group A (M=2.40, SD= 1.102) was significantly different from the group D (M= 1.30, SD= 1.393, p= 0.010). The group D did not differ significantly from group B (M= 1.63, SD= 1.351, p=0.767), and group C (M= 1.60, SD= 1.404, p=0.819). There was a difference between the group A (M=2.40, SD= 1.102), group B (M= 1.63, SD= 1.351) and group C (M= 1.60, SD= 1.404). However, when the Tukey HSD was used, no statistically significant differences between Group A, B and C were found (p=0.122 and p =0.098).
Conclusions: There was a statistically significant difference in micro leakage between the “slow and gradual polymerization” and the standard polymerization, however no significant differences were found when using the nano-filled or the micro-hybrid composite materials cured with different polymerization regimens.

" lang="fr" xml:lang="fr" /> Material and methods: One hundred twenty Class II cavities were prepared at the mesial and the distal side of human extracted premolars. The teeth were randomly divided into four groups (n=15). In each tooth the mesial Class II cavities were restored with the micro-hybrid resin composite Filtek Z250 (3M ESPE) and the distal Class II cavities were restored with the nano-filled resin composite Filtek Supreme (3M ESPE) The light curing unit used in this study was a conventional quartz tungsten halogen (QTH) curing light, the QHL 75 (Dentsply) modified by adding a regulating electronic device, controlled by a special software that gives 4 different modes of polymerization as follows:

The teeth were stored in water at 37°C for 48 hours, then finished and subjected to thermocycling (3000 cycles between 5°C and 55°C). All the teeth were immersed in 2% methylene blue solution for 12 hours at 37°C, sectioned, and evaluated at the gingival margins. Data were statistically analyzed by two-way analysis of variance followed by Tukey HSD multiple comparisons.
Results: The main effect for the type of composites (p= 0.682), and the interaction effect (p=0.678) did not reach statistical significance. There was a statistically significant main effect for the type of polymerization used (p=0.014). Post-hoc comparisons using the Tukey HSD test indicated that the mean score for the Group A (M=2.40, SD= 1.102) was significantly different from the group D (M= 1.30, SD= 1.393, p= 0.010). The group D did not differ significantly from group B (M= 1.63, SD= 1.351, p=0.767), and group C (M= 1.60, SD= 1.404, p=0.819). There was a difference between the group A (M=2.40, SD= 1.102), group B (M= 1.63, SD= 1.351) and group C (M= 1.60, SD= 1.404). However, when the Tukey HSD was used, no statistically significant differences between Group A, B and C were found (p=0.122 and p =0.098).
Conclusions: There was a statistically significant difference in micro leakage between the “slow and gradual polymerization” and the standard polymerization, however no significant differences were found when using the nano-filled or the micro-hybrid composite materials cured with different polymerization regimens.

" />

Ce site utilise des cookies afin d'améliorer la navigation et mesurer la fréquentation. Pour en savoir plus, cliquez ici

bannière promotionnelle

Odonto-Stomatologie tropicale

« Effect of different modes of light curing and resin composites on microleakage of Class II restorations - Part II »

publié en Anglais dans Odonto-Stomatologie tropicale 126 - Juin 2009 - 29-37.

Cet article est actuellement coté note(4,3 étoiles) par les abonnés de APIDPM Santé tropicale.

Consulté 5123 fois - Téléchargé 103 fois - Evalué 6 fois.
 Aucun commentaire n'a encore été ajouté à propos de cet article

Retour


Notez cet article


Vous souhaitez réagir à cet article ?

photo_profil
Rédiger un commentaire Commentaire de de (), le samedi 6 décembre 2025

Retour



CONTACTEZ-NOUS

Adresse

Téléphone

CARTE DU SITE

Revue MAF

Revue OST

Actualités

Rubriques spécialités

Webinaires

Espaces labos

Valid XHTML 1.0 Strict CSS Valide !